JUTAIPEEK®GF30 SHEET, PEEK GF30 SHEET, PEEK sheet profile contains 30% short-cut glass fibers, which significantly reduce the expansion rate of PEEK and increase its flexural modulus. This grade is well-suited for structural applications that require enhanced strength, stiffness, or stability, especially in temperatures exceeding 150°C. The color of glass-filled PEEK is light brown or brownish.
JUTAIPEEK®GF30 SHEET, PEEK GF30 SHEET, PEEK sheet profile contains 30% short-cut glass fibers, which significantly reduce the expansion rate of PEEK and increase its flexural modulus. This grade is well-suited for structural applications that require enhanced strength, stiffness, or stability, especially in temperatures exceeding 150°C. The color of glass-filled PEEK is light brown or brownish.
● Excellent chemical resistance
● High-temperature resistance
● Higher strength and stiffness compared to unfilled PEEK
● Lower thermal expansion than unfilled PEEK
● Not affected by prolonged exposure to hot water or steam
● Extremely low moisture absorption
Applications:
● Aerospace components
● Electrical connectors
● Electrical housings
● Semiconductor components
● Structural parts
● Excellent chemical resistance
● High-temperature resistance
● Higher strength and stiffness compared to unfilled PEEK
● Lower thermal expansion than unfilled PEEK
● Not affected by prolonged exposure to hot water or steam
● Extremely low moisture absorption
Applications:
● Aerospace components
● Electrical connectors
● Electrical housings
● Semiconductor components
● Structural parts
Use a lathe or milling machine to remove the surface heat treatment aging layer, generally removing 0.5-1 mm.
Select PCD-coated tools for milling processing.
Use PCD-coated drill bits, and follow the principle of drilling small holes before expanding them.
Ensure sufficient cooling with cutting fluid during processing to prevent burning and sticking.
It is recommended to use water-soluble cutting fluids.
Product Storage Instructions
Store in a place away from light, moisture, and oily substances.
If not in use, please wrap it in a protective film.
Use a lathe or milling machine to remove the surface heat treatment aging layer, generally removing 0.5-1 mm.
Select PCD-coated tools for milling processing.
Use PCD-coated drill bits, and follow the principle of drilling small holes before expanding them.
Ensure sufficient cooling with cutting fluid during processing to prevent burning and sticking.
It is recommended to use water-soluble cutting fluids.
Product Storage Instructions
Store in a place away from light, moisture, and oily substances.
If not in use, please wrap it in a protective film.
Performance | Test Method | Unit | PEEK Natural |
Color | beige | / | Beige |
Density | ISO1183-1 | g/cm3 | 1.3 |
Tensile Strength | ISO 527-2 | MPa | ≥100 |
Tensile Modulus | ISO 527-2 | GPa | ≥4.0 |
Elongation At Break | ISO 527-2 | % | ≥25 |
Charpy Impact Strength (Notched) | ISO 179 | kJ/m2 | ≥4.0 |
FlexuralStrength | ISO 178 | MPa | ≥150 |
Flexural Modulus | ISO 178 | GPa | ≥3.5 |
Rockwell Hardness | ISO 2039-2 | M | ≥100 |
Shore D Hardness | ISO 868 | Shore D | ≥85 |
Coefficient of Linear Thermal Expansion | ISO 11359-2 | 10-6/K | ≤65 |
Long-term Service Temperature | UL 746B | ℃ | 250 |
Heat Deflection Temperature | ISO 75-2 | ℃ | ≥150 |
WaterAbsorption | ISO 62 | % | ≤0.1 |
Flammability Resistance | UL94 | / | V-0 |
Volume Resistivity | IEC 62631-3-1 | Q ·cm | 1014-1016 |
Dielectric Strength | IEC 60243-1 | kV/mm | ≥15 |
DielectricConstant(1MHz) | IEC 62631-2-1 | / | 3.4 |
Dielectric Loss(1MHz) | IEC 62631-2-1 | / | 0.086 |
Performance | Test Method | Unit | PEEK Natural |
Color | beige | / | Beige |
Density | ISO1183-1 | g/cm3 | 1.3 |
Tensile Strength | ISO 527-2 | MPa | ≥100 |
Tensile Modulus | ISO 527-2 | GPa | ≥4.0 |
Elongation At Break | ISO 527-2 | % | ≥25 |
Charpy Impact Strength (Notched) | ISO 179 | kJ/m2 | ≥4.0 |
FlexuralStrength | ISO 178 | MPa | ≥150 |
Flexural Modulus | ISO 178 | GPa | ≥3.5 |
Rockwell Hardness | ISO 2039-2 | M | ≥100 |
Shore D Hardness | ISO 868 | Shore D | ≥85 |
Coefficient of Linear Thermal Expansion | ISO 11359-2 | 10-6/K | ≤65 |
Long-term Service Temperature | UL 746B | ℃ | 250 |
Heat Deflection Temperature | ISO 75-2 | ℃ | ≥150 |
WaterAbsorption | ISO 62 | % | ≤0.1 |
Flammability Resistance | UL94 | / | V-0 |
Volume Resistivity | IEC 62631-3-1 | Q ·cm | 1014-1016 |
Dielectric Strength | IEC 60243-1 | kV/mm | ≥15 |
DielectricConstant(1MHz) | IEC 62631-2-1 | / | 3.4 |
Dielectric Loss(1MHz) | IEC 62631-2-1 | / | 0.086 |
PEEK GF30 Sheet Specification | ||
Dimension | Length(mm) | Weight(kg) |
6 x 620 | 1000 | 7. 17 |
8 x 620 | 1000 | 9.56 |
10 x 620 | 1000 | 11.47 |
12 x 620 | 1000 | 13.38 |
15 x 620 | 1000 | 16.73 |
16 x 620 | 1000 | 18. 17 |
20 x 620 | 1000 | 21.99 |
25 x 620 | 1000 | 26.77 |
30 x 620 | 1000 | 31.55 |
40 x 620 | 1000 | 41. 11 |
50 x 620 | 1000 | 50.55 |
PEEK GF30 Sheet Specification | ||
Dimension | Length(mm) | Weight(kg) |
6 x 620 | 1000 | 7. 17 |
8 x 620 | 1000 | 9.56 |
10 x 620 | 1000 | 11.47 |
12 x 620 | 1000 | 13.38 |
15 x 620 | 1000 | 16.73 |
16 x 620 | 1000 | 18. 17 |
20 x 620 | 1000 | 21.99 |
25 x 620 | 1000 | 26.77 |
30 x 620 | 1000 | 31.55 |
40 x 620 | 1000 | 41. 11 |
50 x 620 | 1000 | 50.55 |